CRC Industries UK Ltd.
Castlefield Industial Estate, Wylds Rd, Bridgwater,
Somerset,  UK, TA64DD
Tel.: (+44)(0)1278 727200  Fax: (+44)(0)1278 425644

Material Safety Data Sheet Regulation EC No 1907/2006 Art.31

Productname : FLAW DETECTOR PENETRANT Creationdate : 23.11.10
Ref.Nr.: UK10068-3-231110 Replaces: 12.01.09

1. IDENTIFICATION OF PRODUCT AND COMPANY   

 

Productname : FLAW DETECTOR PENETRANT
Aerosol

 

Application :

Welding Products

 

Company :

CRC Industries UK Ltd.
Castlefield Industial Estate, Wylds Rd, Bridgwater,
Somerset,
UK, TA64DD
Tel.: (+44)(0)1278 727200
Fax: (+44)(0)1278 425644
E-mail : hse.uk@crcind.com
 
In case of emergency : (+44)(0)1278 727200
 

Subsidiaries

 

Tel

Fax

CRC Industries Europe Touwslagerstraat 1 9240 Zele Belgium (+32) (0) 52 / 45 60 11 (+32) (0) 52 / 45 00 34

CRC Industries Finland

Asemanrinne 13, 08500 Lohja AS

(+358)(0)19/32921

(+358)(0)19/383676

CRC Industries France

12, Bld des Martyrs de Chateaubriant F-95102 Argenteuil Cédex

(+33)(0)1/34112000

(+33)(0)1/34110996

CRC Industries Deutschland

Südring 9, 76473 Iffezheim

(+49)(0)7229/3030

(+49)(0)7229/303266

CRC Industries Iberia

Gremio del cuero S/N, 40195 Segovia

(+34)921/427546

(+34)921/436270

CRC Industries Sweden

Kryptongatan 14, 43153 Mölndal

(+46)(0)31/7068480

(+46)(0)31/273991

2. HAZARD IDENTIFICATION   

Health and Safety :

Extremely Flammable
Repeated exposure may cause skin dryness or cracking.
(propane/butane propellant)
Remark: Preparations classified as harmful on the basis of an aspiration hazard need not be labelled as harmful with R65 when placed on the market in aerosol containers or in containers fitted with a sealed spray attachment. (EU-Directive 67/548 Annex VI 9.4)

Environment :

Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment.

Other hazards :

Pressurised container: protect from sunlight and do not expose to temperatures exceeding 50°C. Do not pierce or burn, even after use. Do not spray on a naked flame or any incandescent material.
Without adequate ventilation formation of explosive mixtures may be possible.

3. COMPOSITION AND INFORMATION ON COMPONENTS   

Hazardous ingredientCAS-nbr.EINECSw/w %symbolR-phrases*Notes
ethylbenzene100-41-4202-849-4<0.25F,Xn11-20A
(Z)-N-methyl-N-(1-oxo-9-octadecenyl)glycine110-25-8203-749-3<1Xi,N38-41-50/53
xylene1330-20-7215-535-7<1Xn10-20/21-38A
Distillates (petroleum), hydrotreated light; Kerosine - unspecified64742-47-8265-149-830-60Xn65-66B
Hydrocarbons,C3-4-rich, petroleum distillate Petroleumgas (1,3-butadiene < 0.1%)68512-91-4270-990-930-60F+12K
2-Naphthalenol, 1-[[4-(phenylazo)phenyl]azo]-, ar-heptyl ar',ar''-Me derivs.92257-31-3296-120-81-5Xn62
fatty alcohol ethoxylate (polymer)1-5Xn22-41
Explanation notes
A : substance with Community workplace exposure limit
B : substance with national established workplace exposure limit
K : not classified as carcinogen, less than 0.1% w/w 1,3-butadiene (Einecs-nr. 203-450-8)
(* Explanation risk-phrases : see chapter 16)

4. FIRST AID MEASURES   

General Advice :

The usual precautions for handling chemicals should be observed
If any symptoms should occur, seek medical advice.

Contact with eyes :

If substance has got into eyes, immediately wash out with water for at least 15 minutes
Seek medical advice

Contact with skin :

Wash with water and soap.
Seek medical attention if irritation persists

Inhalation :

Fresh air, keep warm and at rest.

Ingestion :

Ingestion is unlikely to occur
If swallowed do not induce vomiting because of risk of aspiration into the lungs. If aspiration is suspected obtain immediate medical attention

5. FIRE-FIGHTING MEASURES   

Flash point (without propellant):

> 70 °C (Closed Cup)

Explosion limits : upper limit :

Not available.

lower limit :

Not available.

Extinguishing media :

foam, carbon dioxide or dry agent

Fire-fighting procedures :

Keep container(s) exposed to fire cool, by spraying with water

Unusual exposure hazard :

Aerosols may explode if heated above 50°C

6. ACCIDENTAL RELEASE MEASURES   

Personal precautions :

Shut off all ignition sources
Ensure adequate ventilation
Wear suitable protective clothing and gloves.

Environmental precautions :

Do not allow to enter public sewers and watercourses

Cleaning methods :

Absorb spillage in suitable inert material

7. HANDLING AND STORAGE    

Handling procedures :

Use only in well ventilated areas
Keep away from heat and sources of ignition
Do not spray on a naked flame or incandescent material.
Do not pierce or burn aerosols, even after use.
Do not breathe aerosols or vapours.
Avoid contact with skin and eyes.

Storage procedures :

Pressurized container : protect from sunlight and do not expose to temperatures exceeding 50°C.
Keep in a cool, dry, well ventilated place
Keep out of reach of children.

8. EXPOSURE CONTROL AND PERSONAL PROTECTION   

Control procedures :

Ensure adequate ventilation
Keep away from heat and sources of ignition
Take precautionary measures against static discharges

Personal protection :

Take precautions to avoid contact with skin and eyes when handling the product.
Use only in well ventilated areas

inhalation :

In case of insufficient ventilation, wear suitable respiratory equipment.
(Filter type AX)

hands and skin :

Wear suitable protective gloves
(nitrile)

eyes :

Wear safety goggles.

Exposure limits :


Hazardous ingredientCAS-nbr.method
EU established exposure limits:
ethylbenzene100-41-4TWA100 ppm
STEL200 ppm
xylene1330-20-7TWA50 ppm
STEL100 ppm

9. PHYSICAL AND CHEMICAL PROPERTIES (for aerosols without propellant)   

Apperance : physical state :

Propane/butane propelled liquid.

colour :

Red.

odour :

Solvent.

Boiling point/range :

Not available.

Relative density :

0.828 g/cm3 (@ 20°C).

pH :

Not applicable.

Vapour pressure :

Not available.

Relative vapour density :

Not available.

Solubility in water :

Emulsifies with water

Flash point :

> 70 °C (Closed Cup)

Auto-ignition :

> 200 °C

Viscosity :

Not available.

Viscosity :

Not available.

Evaporation rate :

Not available.

10. STABILITY AND REACTIVITY   

Conditions to be avoided :

Pressurized container : protect from sunlight and do not expose to temperatures exceeding 50°C.
Keep away from heat and sources of ignition

Materials to be avoided :

Strong oxidising agent

Hazardous decomposition compounds :

CO,CO2

11. TOXICOLOGICAL INFORMATION   

Inhalation :

Excessive inhalation of solvent vapours may give rise to nausea, headaches and dizziness

Ingestion :

Ingestion is unlikely to occur
If swallowed do not induce vomiting because of risk of aspiration into the lungs. If aspiration is suspected obtain immediate medical attention

Skin contact :

May cause irritation.

Eye contact :

May cause irritation.

12. ECOLOGICAL INFORMATION   

Other adverse effects :

Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment.

Do not allow to enter public sewers and watercourses

13. WASTE DISPOSAL   

Product :

Do not discharge into drains or the environment, dispose to an authorised waste collection point.
This material and its container must be disposed of in a safe way.

Disposal should be in accordance with local, state or national legislation

14. TRANSPORT   

UN-number :

1950

Road/Rail - ADR/RID :

UN1950 Aerosols Class : 2, PG : NA, Class code : 5F, Label : 2.1, Tunnel-code : (D)

Sea - IMDG :

UN1950 Aerosols Class : 2, PG : NA, Label : 2.1
 

EmS

F-D, S-U

Air - IATA/ICAO :

UN1950 Aerosols, flammable Class : 2, PG : NA, Label : 2.1
 
 
 

15. REGULATORY INFORMATION   

Warning symbol(s) :

F+ : EXTREMELY FLAMMABLE

Risk-phrase(s) :

R66: Repeated exposure may cause skin dryness or cracking.
R52/53: Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment.

Safety-phrase(s) :

S2: Keep out of the reach of children.
S16: Keep away from sources of ignition - No smoking.
S23: Do not breathe vapours/spray.
S24/25: Avoid contact with skin and eyes.
S35: This material and its container must be disposed of in a safe way.
S51: Use only in well-ventilated areas.
Pressurised container: protect from sunlight and do not expose to temperatures exceeding 50°C. Do not pierce or burn, even after use. Do not spray on a naked flame or any incandescent material. Without adequate ventilation formation of explosive mixtures may be possible.
Classified according to Dir. 2008/47/EC amendment of the aerosol dispenser directive 75/324/EEC.
Classification according to EU-directive 99/45/EC
Remark: Preparations classified as harmful on the basis of an aspiration hazard need not be labelled as harmful with R65 when placed on the market in aerosol containers or in containers fitted with a sealed spray attachment. (EU-Directive 67/548 Annex VI 9.4)

16. OTHER INFORMATION   

This product should be stored, handled and used in accordance with good industrial hygiene practices and in conformity with any legal regulation.
The information contained herewith is based on the present state of our knowledge and is intended to describe our products from the point of view of safety requirements. It does not guarantee any specific properties.
Apart from any fair dealing for purposes of study, research and review of health, safety and environmental risks, no part of these documents may be reproduced by any process without written permission from CRC.

REVISIONS IN CHAPTRE :

2,3,15

*Explanation risk-phrases:

R10: Flammable.
R11: Highly flammable.
R12: Extremely flammable.
R20: Harmful by inhalation.
R20/21: Harmful by inhalation and in contact with skin.
R22: Harmful if swallowed.
R38: Irritating to skin.
R41: Risk of serious damage to eyes.
R50/53: Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.
R62: Possible risk of impaired fertility.
R65: Harmful: may cause lung damage if swallowed.
R66: Repeated exposure may cause skin dryness or cracking.

 

This Material Safety Data Sheet may already have been revised at this moment for reason such as legislation, availability of components and newly acquired experiences. The latest and only valid version of this Material Safety Data Sheet will be sent to you upon simple request or can be found on our website : www.crcind.com. We recommend you to register on this website for this product so you will be able to receive any future updated version automatically.